Identify Partitions

B Series floor plans 1:100

  • Unique identification tag for each drylining partition type and unique number for every blockwork wall (see NOTE)
  • Concrete walls are already documented in V series drawings

Note

Blockwork walls are often constructed as full height for the purpose of acoustic or fire protection. If services, e.g. mechanical ducts are going through them, blockwork walls need to be drawn in elevation to set-out the penetrations. For that reason the walls need to be given a unique tag for every straight run of the wall. If there are no penetrations through blockwork walls, a blockwork type code (with corresponding detail) will suffice

Describe construction only

A Series legend sheet

  • Key - description of the partition construction code
INS-06Thermal Insulation - Under Concrete - 35mm (R1.66) thick Partitions 05-100INS-13Acoustic Insulation (Walls) -100mm thick Partitions 05-100 INS-07Thermal insulation (ceilings) - Not Used Suspended Ceilings05-050 . . . . Partitions . . Partitions . . A1Internal Acoustic Rated Partition - Nominal width 100mm & 40 Rw Partitions 05-100F1Internal Fire & Acoustic Rated Partition - Nominal width 130mm , FRL: -Partitions 05-100 A2Internal Acoustic Rated Partition - Nominal width 115mm & 45 Rw Partitions 05-100F2Internal Fire & Acoustic Rated Partition - Nominal width 130mm , FRL: -Partitions 05-100 A3Internal Acoustic Rated Partition - Nominal width 130mm & 51 Rw Partitions 05-100F3Internal Fire & Acoustic Rated Partition - Nominal width 130mm , FRL: -Partitions 05-100 A4Internal Acoustic Rated Partition - Nominal width 250mm & 60+ Rw Partitions 05-100F4Internal Fire & Acoustic Rated Partition - Nominal width 155mm , FRL: Partitions 05-100 A5Internal Acoustic Rated Partition - Nominal width 115mm & 40 Rw Partitions 05-100F5Internal Fire & Acoustic Rated Partition - Nominal width 310mm , FRL: Partitions 05-100 A6Internal Acoustic Rated Partition - Nominal width 130mm & 46 Rw Partitions 05-100F6Internal Fire & Acoustic Rated Partition -No minal width 125mm , FRL: -Partitions 05-100 A7Internal Acoustic Rated Partition - Nominal width 145mm & 51 Rw Partitions 05-100F7Internal Fire Rated Partition - Nominal widt h 125mm , FRL: 120/120/120 Partitions 05-100 . . . . Internal Windows/ Partitions . . Internal Windows/ Partitions . . G1Internal Glazed Partition - 2700mm high Internal Glazed Partitions04-500G7Internal Glazed Partition - 2700mm high Internal Glaz ed Partitions04-500 G2Double Glazed Integral Venetian Blinds - Lidco 715 System Internal Glazed Partitions04-500G8Double Glazed Integral Venetian Bl inds - Lidco 715 System & 600mm x Internal Glazed Partitions04-500 G3Internal Glazed Partition - Lidco 715 Internal Glazed Partitions04-500G9Internal Glazed Partition - Lidco 715 System & 1500mm high Internal Glazed Partitions04-500

G Series internal spaces plans 1:40

  • (If provided - otherwise refer direct from 1:100 plans in B series)
  • Make reference to 1:5 details in K series

K Series interface details 1:5

  • Construction of the detail only - do not describe applied finishes e.g. paint, sealant, etc
  • (Generic) internal partitions-tointernal partitions plan details (if required - not needed if it’s common construction)
  • (Location specific) internal partitions-to-external wall plan details
  • (Location specific) internal partitions-to-ceiling section details
  • (Location specific) internal partitions-to-floor section details
  • Do not redraw common details. Make reference to proprietary system in the specification instead.