Describe wall protection systems

F Series room schedule

  • The systems are identified and located by listing the materials and finishes codes under the | WALL PROTECTION | criteria

Note

There is a strong preference for documenting the wall protection systems in the room schedule. System codes allocated to the rooms in the room schedule spreadsheet sufficiently describe the wall protection items in the majority of cases.

The NOTE column in the room schedule is used to describe the specific location of an item e.g.‘CRASH RAIL TRM-02 TO NORTH WALL, HANDRAIL TRM-05 TO SOUTH WALL

For more complex areas instead of trying to code it, write a note in schedule ‘FOR DETAILS REFER TO DRAWING AR-G-**-**

Describe wall protection systems

A Series legend sheet

  • Key - description of wall protection items codes; reference to specification section
TIL-01 Vitrified ceramic floor tiling: Klingenberg/Graphite Mix Tiling 05-400 TIL-03 Vitrified ceramic floor tiling - Metz Ceramic tiles Tiling 05-400 TIL-02 Ceramic wall tiling - Classic Ceramics: Matt White Tiling 05-400 TIL-04 Ceramic wall tiling - Classic Ceramics: Matt White Tiling 05-400 . . . . Trims/Skirtings/Architraves . . Trims/Skirtings/Architraves . . TRM-01 Handrail and Crash Rail Combined Wall Protection 06-150 TRM-10 Aluminium Door Threshold Plate Resilient Floor Finishes05-550 TRM-02 Single Corner Guard Wall Protection 06-150 TRM-11 Aluminium skirtings Resilient Floor Finishes05-100 TRM-03 Single Crash Rail Wall Protection 06-150 TRM-12 Double Corner Guards Wall Protection 06-150 TRM-04 MDF skirtings Resilient Floor Finishes05-550 TRM-13 Double Crash Rail Wall Protection 06-150 TRM-05 Aluminium skirtings Resilient Floor Finishes05-100 TRM-14 Handrail and Crash Rail Combined Wall Protection 06-150 TRM-06 Double Corner Guards Wall Protection 06-150 TRM-15 MDF skirtings Resilient Floor Finishes05-550 TRM-07 Aluminium Door Threshold Plate Resilient Floor Finishes05-550 TRM-16 Single Corner Guard Wall Protection 06-150 TRM-08 Double Crash Rail Wall Protection 06-150 TRM-17 Single Corner Guard (Full Height) Wall Protection 06-150 TRM-09 Single Corner Guard (Full Height) Wall Protection 06-150 TRM-18 Single Crash Rail Wall Protection 06-150 Water Proofing Systems . . Water Proofing Systems . . WPRS-01 Tanking Membrane Waterproofing 04-050 WPRS-06 Tanking Membrane Waterproofing 04-050

F Series room schedule

  • Reference complex areas which can not be scheduled to 1:50 plans in G series
LEVEL 1 LEVEL 01 Block E E1E1001Concourse SCR 1FF 04 BRCK CLG 1PT 2 E1E1002Concourse CLG 1PT 2 E1E1002Concourse CLG 1PT 2 E1E1003Concourse SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 E1E1003Concourse (FHR) SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 E1E1003Concourse (EDB) SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 BRD 4PT 2 E1E1003Concourse SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 CLG 1PT 2 E1E1004Patient Circulation CONCFF 04 PLA 2 PT 7CLG 4 CLG 1PT 2 E1E1005Patient Circulation CONCFF 04SKI 01PLA 2 PT 7CLG 4 E1E1006Circulation Service/Staff CONCFF 05SKI 01PLA 2 PT 7CLG 4 E1E1006Circulation Service/Staff (FHR) CONCFF 05 PLA 2 PT 4CLG 4 E1E1006Circulation Service/Staff CONCFF 05 PLA 2 PT 4CLG 4 E1E1007Circulation Service/Staff CONCFF 05 PLA 2 PT 4CLG 4 E1E1008Patient Circulation CONCFF 05SKI 02PLA 1 PT 4CLG 4 Block Level Room Number Room name Floor Finish Skirting Substrate material Finish Substrate material Finish Walls Substrate material Finish Ceiling Bulkhead Note Refer to drawing AR Q 01 16 Refer to drawing AR Q 01 18 Substrate material LEVEL 1 LEVEL 01 Block E E1E1001Concourse SCR 1FF 04 BRCK CLG 1PT 2 E1E1002Concourse CLG 1PT 2 E1E1002Concourse CLG 1PT 2 E1E1003Concourse SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 E1E1003Concourse (FHR) SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 E1E1003Concourse (EDB) SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 BRD 4PT 2 E1E1003Concourse SCR 1FF 04SKI 01PLA 1 PT 4CLG 4 CLG 1PT 2 E1E1004Patient Circulation CONCFF 04 PLA 2 PT 7CLG 4 CLG 1PT 2 E1E1005Patient Circulation CONCFF 04SKI 01PLA 2 PT 7CLG 4 E1E1006Circulation Service/Staff CONCFF 05SKI 01PLA 2 PT 7CLG 4 E1E1006Circulation Service/Staff (FHR) CONCFF 05 PLA 2 PT 4CLG 4 E1E1006Circulation Service/Staff CONCFF 05 PLA 2 PT 4CLG 4 E1E1007Circulation Service/Staff CONCFF 05 PLA 2 PT 4CLG 4 E1E1008Patient Circulation CONCFF 05SKI 02PLA 1 PT 4CLG 4 Block Level Room Number Room name Floor Finish Skirting Substrate material Finish Substrate material Finish Walls Substrate material Finish Ceiling Bulkhead Note Refer to drawing AR Q 01 16 Refer to drawing AR Q 01 18 Substrate material

G Series internal spaces elevations 1:50

(if provided)

  • Describe wall protection items using systems codes
  • Make reference to 1:5 interface details in K series

K Series interface details 1:5

  • Detail wall protection systems using systems codes

Z Series wall protection specifications

C. Work under the Subcontract shall be base fixed, with a sliding head connection to the primary structure made from concrete or steel. D. Take every precaution to ensure that no chemical or electrolytic action takes place where dissimilar metals and/ or materials are used together, and to isolate metal components from cementitious surfaces. Necessary insulation shall be provided wherever dissimilar metals come into contact. E. All inaccessible steel shall be hot dip galvanised. F. All alloys shall be similarly finished to match accepted samples. 3.3 Plasterboard Ceilings A. To AS/NZS 2589. B. Fix, joint and finish in accordance with the system manufacturer's instructions. Provide movement joints for the area of ceiling and coordinate with structural movement joints. C. Boards shall be screwed neatly and accurately without damaging surfaces. Any damaged board shall be replaced. D. Heads of screws shall be set below the surface of boards and filled to form a flush surface. E. Joints of boards applied in two or more layers shall be staggered ensuring that all edges and ends are fully supported and screwed to grid members. F. Unless specified to a higher standard, flush plasterboard ceilings shall achieve a level 4 finish in accordance with AS/NZS 2589. G. Suspension system shall be suitably robust and installed in accordance with the manufacturer's recommendations. H. Install within the zones indicated on the Design Drawings and incorporate a sliding head connection to the primary support structure. 3.4 Ceiling Penetrations A. Where partitions terminate at the suspended ceiling (ie the suspended ceiling is continuous above the partition), ceiling penetrations within 1000mm of the partition shall be acoustically treated. 3.5 Movement Joints A. Movement joints shall be as shown on the Design Drawings and installed to the manufacturer's recommendations. B. Provide movement joints as appropriate for the area of ceiling and/ or to coincide with movement joints in the surrounding structure. 3.6 Fire Stopping A. All gaps at junctions with walls, cavity barriers, ducts, pipes and other penetrations shall be sealed using tightly packed mineral wool, intumescent sealant or other fireproof material to prevent penetration of smoke and flame. B. The installation shall be in accordance with the manufacturer's approved tested prototypes. 3.7 Air Plenum Barrier A. Air plenum barriers shall comprise rigid or semi-rigid non-porous sheets with smooth non-dusting surfaces having the same fire spread rating as that required for membrane materials exposed within the void. B. Air plenum barriers shall be fixed securely at perimeters and joints, using methods recommended by the barrier manufacturer to ensure permanent stability. All edges and joints shall be effectively sealed to prevent air leakage. 3.8 Installation Tolerances A. Grid dimensions as shown on the Design Drawings shall be maintained ±1mm. B. Finished ceiling levels shall be as shown on the Design Drawings ±2mm in 1000mm length. C. Check all Site dimensions before commencement of installation. D. Accommodate all specified tolerances and differences between actual Site dimensions and dimensions shown on the Shop Drawings. E. Joints between panels shall be consistent, square and flush, being clamped together by the support system. Where gaskets are installed in joints, they shall not vary in width by more than 10% of the width of the gasket in place. F. Panel to panel lipping or plan offset shall not exceed 0.5mm and shall be non-cumulative across any ceiling. G. Grid creep across any ceiling shall not exceed 1.5mm in a 10m length. AR-U-XX-24 Suspended Ceiling Package Suspended Ceilings 01/02/2011 Section 05-050 Tender Issue BVN Architecture 05-050 / 5 Specification SECTION 05-050 -- SUSPENDED CEILINGS 1. GENERAL 1.1 Related Documents A. This work section shall be read in conjunction with the Superintendent's Tender Documents and other related sections of the Specification. 1.2 Outline of Work A. This work section of the Specification, when read in conjunction with the Design Drawings, provides particular requirements with respect to the following: 1. Suspended ceiling systems: a) Acoustic tile ceilings. b) Plasterboard ceilings. 2. Ceiling access panels. 3. Insulation. 4. Movement joints. B. Ensure that all interfaces are fully coordinated prior to commencement. 1.3 Post Subcontract Samples A. In accordance with the Superintendent's Tender Documents provide post Subcontract samples of the following: 1. Paint finishes as specified. 2. 300mm length of support system. 3. Samples of panels, grilles, trims, etc. 4. All fixing types. 5. All insulation materials. 1.4 Mock-ups A. Not required. 1.5 Prototypes A. Not required. 1.6 Benchmark Requirements A. Provide the following quality benchmarks in accordance with the Superintendent's Tender Documents: 1. The first 10m² of each type in location as agreed with the Superintendent. 1.7 Witness Points A. The Superintendent shall be invited to inspect work under the Subcontract at the following stages (a minimum of two working days notice shall be given): 1. Completed ceiling before Site painting, if applicable. 2. The suspension system before installation of the ceiling panels or lining. 3. Set out of all movement joints. 1.8 Subcontractor's Subcontractors A. Submit name and contact details of proposed manufacturers and Subcontractor's Subcontractors. 1.9 Shop Drawings A. Submit Shop Drawings showing the relevant details of the ceiling system as follows: 1. Grid set out and extent of all ceiling types. Show all services outlets and demonstrate that all services have been adequately coordinated. 2. Details: Large scale details of construction, suspension system, methods of assembly, trim and fixing, showing dimensions, clearances and tolerances. 3. Partition attachment: Method of attaching heads of partitions to the ceiling support members. 1.10 Warranties A. Prior to Practical Completion a written warranty shall be submitted to the Superintendent for the following: AR-U-XX-24 Suspended Ceiling Package Suspended Ceilings 01/02/2011 Section 05-050 Tender Issue BVN Architecture 05-050 / 1 Specification 1. All ceiling systems shall withstand temperature and humidity without visible sag for 15 years. 1.11 Test Requirements A. Provide evidence of independent tests carried out to demonstrate that the products comply with the Specification or carry out such tests necessary to demonstrate compliance. B. Such tests to demonstrate compliance in respect of the following criteria: 1. Fire resistance. 2. Air leakage. 3. Acoustic integrity. 4. Structural stability. 2. PRODUCTS 2.1 Type CLG-01 Suspended Plasterboard Ceiling A. 13mm gypsum plasterboard lining fixed to the suspended ceiling system at 600mm centres. B. Upstands, bulkheads, coffers and the like as shown on the Design Drawings shall have internal and external stainless steel corner stopping beads. C. Where plasterboard ceilings abut walls, provide Rondo P50 shadow stopping angles. Gaps between the wall and the metal edge of the stopping angle shall be filled with a paintable flexible sealant. 2.2 Type CLG-02 Suspended Moisture Resistant Plasterboard Ceiling A. 13mm moisture resistant plasterboard lining fixed to suspended ceiling system at 600mm maximum centres. B. Where plasterboard ceilings abut walls, provide Rondo P50 shadow stopping angles. Gaps between the wall and the metal edge of the stopping angle shall be filled with a paintable flexible sealant. 2.3 Type CLG-03 Suspended Plasterboard Ceiling - Curved Profile A. 13mm gypsum plasterboard lining, curved to profiles as detailed on the Design Drawings. 1. Fixed to the suspended ceiling system at maximum 600mm centres, and as required to support the required curvature without deviation. B. Upstands, bulkheads, coffers and the like as shown on the Design Drawings shall have internal and external stainless steel corner stopping beads. C. Where plasterboard ceilings abut walls, provide Rondo P50 shadow stopping angles. Gaps between the wall and the metal edge of the stopping angle shall be filled with a paintable flexible sealant. 2.4 Type CLG-04 Suspended Acoustic Tile Ceiling - 40CAC A. 1200mm x 600mm lay in acoustic ceiling tiles. B. Manufacturer/ reference: CSR Fricker Cosmos range, or acceptable equivalent. 1. Code: CSR FCS 600ANDB20. C. Grid: CSR USG Donn DX Steel Grid system, or acceptable equivalent. D. Performance requirements: 1. CAC: 40Db. 2. NRC: 0.65. E. Suspension system: As supplied by CSR Fricker Ceiling Systems or acceptable equivalent. F. Perimeter trim to comprise matching metal trims, fixed to the perimeter at not more than 450mm centres. 1. Shadowline wall angles fixed to partition walls at not more than 450mm centres to match ceiling grid system. G. Structural soffit: Concrete slab soffit or underside of metal deck roof as applicable. H. Ceiling height shall be as nominated on the Design Drawings. I. Allow for the integration of services shown on the Design Drawings. 2.5 Type CLG-05 Suspended Acoustic Tile Ceiling - Hygionic 40CAC A. 1200mm x 600mm lay in hygienic acoustic ceiling tiles. B. Manufacturer/ reference: CSR Fricker Cosmos range, or acceptable equivalent. 1. Code: CSR FCS 600ANDB20S. AR-U-XX-24 Suspended Ceiling Package Suspended Ceilings 01/02/2011 Section 05-050 Tender Issue BVN Architecture 05-050 / 2 Specification C. Grid: CSR USG Donn DX Steel Grid system, or acceptable equivalent. D. Performance requirements: 1. CAC: 40Db. 2. NRC: 0.65. E. Suspension system: As supplied by CSR Fricker Ceiling Systems or acceptable equivalent. F. Perimeter trim to comprise matching metal trims, fixed to the perimeter at not more than 450mm centres. 1. Shadowline wall angles fixed to partition walls at not more than 450mm centres to match ceiling grid system. G. Structural soffit: Concrete slab soffit or underside of metal deck roof as applicable. H. Ceiling height shall be as nominated on the Design Drawings. I. Allow for the integration of services shown on the Design Drawings. 2.6 Suspension System Generally A. Extent of system: Include hangers, fixings, main runners, cross members, primary channels, perimeter trims, splines, clips, bracing, bridging, etc., which are necessary to complete the ceiling system and achieve the performance specified. B. Materials: Steel. C. Top fixings: Suitable for structure. D. Hangers: Solid steel rods. E. Grid type: As specified above. F. Colour: White. 2.7 Perimeter Trims Generally A. Type: Wall angle as per manufacturer's written instructions or acceptable equivalent. B. Rondo P50 Shadowline stopping angle to plasterboard and fibre cement ceilings. C. Rondo Shadowline wall angle to acoustic tile ceilings. D. Fixings to perimeters: BZP raised head screws. E. Fixing centres (maximum): 450mm. 2.8 Plasterboard A. Gypsum core plasterboard manufactured by Boral, CSR or acceptable equivalent, to AS/NZS 2588. Standard grade classification, with exposed surface suitable for decoration and tapered edges for smooth seamless jointing. 2.9 Moisture Resistant Plasterboard A. Gypsum core plasterboard manufactured by Boral, CSR, or acceptable equivalent, to AS/NZS 2588. Water resistant grade classification with additives to the core and/ or paper liners to reduce the water absorption rate. Exposed surface suitable for decoration and tapered edges for smooth seamless jointing. 2.10 Support Systems and Fixings A. Manufacturer/ reference: Rondo or acceptable equivalent. B. Mild steel suspension systems shall be hot dip galvanised to AS/NZS 4680 with cold rolled channels and sections. C. Aluminium framing members shall be fabricated using only appropriate grades, strengths and thicknesses to provide full structural compliance. The wall thickness of aluminium extrusions shall be sufficient to ensure rigidity in the lengths required in the final installation. D. Fixings and suspension system shall be fully concealed including all hangers, fixings, main runners, cross members, primary channels, perimeter trims, splines, clips, bracing, bridging, etc., which are necessary to complete the installation and achieve the performance specified. E. Corrosion resistant anchors, inserts, fasteners and other such devices shall be used in accordance with Section 08-400. F. Use only continuous profiles free from marks, defects, flaws, steps, waves or any other damage. 2.11 Type AP-02 Ceiling Access Panels A. Manufacturer/ reference: Trafalgar AP-C-WW-600 ceiling access panels. 600mm x 600mm with CP budget rim lock and concealed metal frame, or acceptable equivalent. AR-U-XX-24 Suspended Ceiling Package Suspended Ceilings 01/02/2011 Section 05-050 Tender Issue BVN Architecture 05-050 / 3 Specification B. Quantity: The Subcontractor shall allow one access panel for every 10m² of flush plasterboard ceiling at locations to be advised. C. Match the access panels to the respective ceiling in performance and appearance. D. Provide each access panel with an identification mark. 2.12 Type AP-04 Ceiling Access Panels A. Manufacturer/ reference: Trafalgar AP-C-WW-300 flush ceiling access panels. 300mm x 300mm with CP budget rim lock and concealed metal frame, or acceptable equivalent. B. Match the access panels to the respective ceiling in performance and appearance. C. Provide each access panel with an identification mark. 2.13 Type AP-05 Ceiling Access Panels - Fire Rated A. Manufacturer/ reference: Trafalgar FR-C-WW-6040 fire rated flush ceiling access panels. 600mm x 400mm with CP budget rim lock and concealed metal frame, or acceptable equivalent. B. Match the access panels to the respective ceiling in performance and appearance. C. Provide each access panel with an identification mark. 2.14 Manufacturing Tolerances A. A high degree of accuracy is required in the fabrication of work under the Subcontract in order to ensure accurate assembly on Site. This shall include the requirement to accurately locate repetitive units in relation to gridlines without accumulation of tolerances and that all joints are matched for level and alignment. The manufacturing tolerances below shall be maintained. B. Tile position: 1. Metal ceiling tiles: ±0.5mm in any direction. 2. Fibre ceiling tiles: ±1mm in any direction. C. Face deflection of tiles not exceeding 600mm in any direction: 1. At edge 1mm. 2. At centre 2mm. D. Face deflection of tiles exceeding 600mm in any direction: 1. At edge 1.5mm. 2. At centre 3mm. E. Edge straightness when suspended: 0mm to -0.3mm per metre concave. F. Flatness criterion: 1:1000. G. Squareness: 0.15mm per 300mm length. H. Side flange angle: 90°: 1. +0.5° relative. 2. +2° to face. I. Edge perforated/ plain border: 1. +0.7mm. 2. -0.7mm. 2.15 Factory Applied Finishes A. Prepare panels to receive factory finish. This shall include rinsing, degreasing, sealing and priming in accordance with the manufacturer's instructions. B. Ensure measures taken to guarantee uniformity in texture, colour and appearance without irregularities or distortions following finish applications. 3. EXECUTION 3.1 General A. Design and Installation shall be to AS/NZS 2785. 3.2 Suspension System A. Install the suspension system in accordance with the manufacturer's recommendedations with appropriate fixings to the substrate soffit. B. Install within the fixing zones indicated on the Design Drawings. AR-U-XX-24 Suspended Ceiling Package Suspended Ceilings 01/02/2011 Section 05-050 Tender Issue BVN Architecture 05-050 / 4 Specification B. Quantity: The Subcontractor shall allow one access panel for every 10m² of flush plasterboard ceiling at locations to be advised. C. Match the access panels to the respective ceiling in performance and appearance. D. Provide each access panel with an identification mark. 2.12 Type AP-04 Ceiling Access Panels A. Manufacturer/ reference: Trafalgar AP-C-WW-300 flush ceiling access panels. 300mm x 300mm with CP budget rim lock and concealed metal frame, or acceptable equivalent. B. Match the access panels to the respective ceiling in performance and appearance. C. Provide each access panel with an identification mark. 2.13 Type AP-05 Ceiling Access Panels - Fire Rated A. Manufacturer/ reference: Trafalgar FR-C-WW-6040 fire rated flush ceiling access panels. 600mm x 400mm with CP budget rim lock and concealed metal frame, or acceptable equivalent. B. Match the access panels to the respective ceiling in performance and appearance. C. Provide each access panel with an identification mark. 2.14 Manufacturing Tolerances A. A high degree of accuracy is required in the fabrication of work under the Subcontract in order to ensure accurate assembly on Site. This shall include the requirement to accurately locate repetitive units in relation to gridlines without accumulation of tolerances and that all joints are matched for level and alignment. The manufacturing tolerances below shall be maintained. B. Tile position: 1. Metal ceiling tiles: ±0.5mm in any direction. 2. Fibre ceiling tiles: ±1mm in any direction. C. Face deflection of tiles not exceeding 600mm in any direction: 1. At edge 1mm. 2. At centre 2mm. D. Face deflection of tiles exceeding 600mm in any direction: 1. At edge 1.5mm. 2. At centre 3mm. E. Edge straightness when suspended: 0mm to -0.3mm per metre concave. F. Flatness criterion: 1:1000. G. Squareness: 0.15mm per 300mm length. H. Side flange angle: 90°: 1. +0.5° relative. 2. +2° to face. I. Edge perforated/ plain border: 1. +0.7mm. 2. -0.7mm. 2.15 Factory Applied Finishes A. Prepare panels to receive factory finish. This shall include rinsing, degreasing, sealing and priming in accordance with the manufacturer's instructions. B. Ensure measures taken to guarantee uniformity in texture, colour and appearance without irregularities or distortions following finish applications. 3. EXECUTION 3.1 General A. Design and Installation shall be to AS/NZS 2785. 3.2 Suspension System A. Install the suspension system in accordance with the manufacturer's recommendedations with appropriate fixings to the substrate soffit. B. Install within the fixing zones indicated on the Design Drawings. AR-U-XX-24 Suspended Ceiling Package Suspended Ceilings 01/02/2011 Section 05-050 Tender Issue BVN Architecture